Chapter 4: Programming Commands76
Revision C 12/09
A798-PG00001C
3 = Transmit error status
Bit Status Hex Decimal Function
0 O 00 0 Fixed to o.
1 On 02 2 Fixed to on.
2 O 00 0 Fixed to o.
3 O 00 0 No knife error.
On 08 8 Knife error occurred.
4 On 10 16 Fixed to on.
5 O 00 0 No unrecoverable error.
On 20 32 Unrecoverable error occurred.
6 O 00 0 Thermal printhead temp. and power supply voltage are in range.
On 40 64 Thermal print head temp. or power supply voltage are out of range.
7 O 00 0 Fixed to o
4 = Transmit receipt paper status
Bit Status Hex Decimal Function
0 O 00 0 Fixed to o
1 On 02 2 Fixed to on
2 O 00 0 Paper adequate
On 04 4 Paper low (if paper low sensor enabled)
3 O 00 0 Paper adequate
On 08 8 Paper low (if paper low sensor enabled)
4 On 10 16 Fixed to on
5 O 00 0 Paper present
On 20 32 Paper exhausted
6 O 00 0 Paper present
On 40 64 Paper exhausted
7 O 00 0 Fixed to o